IR HiRel Product Families |
Hybrid DC-DC converter with 50 Vin and +/-12 Vout dual output, 40 W total output power
Last Time Buy Expired
Low Weight < 100 grams
Magnetically Coupled Feedback
38V to 60V DC Input Range
Up to 40W Output Power
Single and Dual Output Models Include 3.3, ±5, ±12 and ±15V
Under-Voltage Lockout
Short Circuit and Overload Protection
Parameter | Value |
---|---|
Total Dose kRad (Si) | 200 |
SEE | 82 |
Total Output Power (W) | 40 |
Nominal Input Voltage | 50 |
Output Voltage (V) | +/- 12 |
IOUT (A) | +/- 2.67 |
Typical Efficiency (%) | 81 |
Operating Temperature | 85°C |
Outputs | Dual |
Qual Level | Radiation Hardened |
IOUT Dual (A) | +/-2.67 |
Input Voltage Min (V) | 38 |
Package | M3GB |
Max Operating Temperature | 125°C |
Input Voltage Max (V) | 60 |
Base Part Status | Last Time Buy Expired |
Output Voltage Dual (V) | +/-12 |
Predicting Mission Life Performance and Reliability of Rad-Hard Power Electronics
Rad Hard MOSFETs Enable Easy Upgrade Of Flight-Proven DC-DC Converter
Space Power Components Answer Calls for Higher Performance Lower Cost
Reducing reliability risks in space missions start with component selection
Board-level qualification testing for rad hard MOSFET packaging
Part # M3GB5012D
Hybrid DC-DC converter with 50 Vin and +/-12 Vout dual output, 40 W total output power
Description | Part Number | Status | Standard Pack Quantity |
---|---|---|---|
K Level Screening, Solder Dipped Leads | M3GB5012D/CKA | LAST_TIME_BUY_EXPIRED | |
Base Model | M3GB5012D | LAST_TIME_BUY_EXPIRED | |
K Level Screening, Gold Plated Leads | M3GB5012D/CKC | LAST_TIME_BUY_EXPIRED |