IR HiRel Product Families |
Hybrid DC-DC converter with 28 Vin and +/-12 Vout dual output, 30 W total output power
Active
Low Weight < 80 grams
Magnetically Coupled Feedback
18V to 40V DC Input Range
Up to 30W Output Power
Single and Dual Output Models Include 1.5, 2.5, 3.3, ±5, 6, ±12 and ±15V
Under-Voltage Lockout
Short Circuit and Overload Protection
Parameter | Value |
---|---|
Total Dose kRad (Si) | 100 |
SEE | 82 |
Total Output Power (W) | 30 |
Nominal Input Voltage | 28 |
Output Voltage (V) | +/- 12 |
IOUT (A) | +/- 2.3 |
Typical Efficiency (%) | 83 |
Operating Temperature | 85°C |
DLA Drawing | 5962-05241 |
DLA Qualified | SMD |
Outputs | Dual |
Qual Level | Radiation Hardened |
RoHS | No |
IOUT Dual (A) | +/-2.3 |
Input Voltage Min (V) | 18 |
Halogen-Free | Yes |
Package | LS |
Max Operating Temperature | 125°C |
Input Voltage Max (V) | 40 |
Base Part Status | Active |
Output Voltage Dual (V) | +/-12 |
Technology | HiRel DC/DC CON |
IR has a long history of providing high-reliability, radiation hardened power management solutions for space flight with products used in over 2000 space programs from launchers to satellites to space exploration vehicles.
Predicting Mission Life Performance and Reliability of Rad-Hard Power Electronics
Rad Hard MOSFETs Enable Easy Upgrade Of Flight-Proven DC-DC Converter
Space Power Components Answer Calls for Higher Performance Lower Cost
Reducing reliability risks in space missions start with component selection
Board-level qualification testing for rad hard MOSFET packaging
Part # LS2812D
Hybrid DC-DC converter with 28 Vin and +/-12 Vout dual output, 30 W total output power
Description | Part Number | Status | Standard Pack Quantity |
---|---|---|---|
Engineering Model | LS2812D/EM | ACTIVE | |
Base Model | LS2812D | OBSOLETE | 1 |
SMD Class K Solder Dipped Leads | 5962-0524101KXA | ACTIVE | 1 |
SMD Class K Gold Plated Leads | 5962-0524101KXC | ACTIVE | 1 |