Aerospace and Defense DC-DC

Hermetic, hybrid, isolated DC-DC converters available with MIL-PRF-38534 Class H qualification and QPLs and unparalleled heritage.

Loading

Aerospace and Defense DC-DC

121 Matching Results

Add to Parts ListAdd to Parts List
Reset FiltersReset Filters

Drag and drop parameters to add, remove, and reorder.

  • DLA Qualified
  • Halogen-Free
  • Technology
  • Part
  • DLA Drawing
  • Base Part Status
  • IOUT Dual (A)
  • IOUT Single (A)
  • Input Voltage Max (V)
  • Input Voltage Min (V)
  • Output Voltage Dual (V)
  • Output Voltage Single (V)
  • Outputs
  • Package
  • Qual Level
  • Total Output Power (W)
  • Typical Efficiency (%)
Part
DLA Drawing
Base Part Status
IOUT Dual (A)
IOUT Single (A)
Output Voltage Dual (V)
Output Voltage Single (V)
Outputs
Package
Qual Level
Total Output Power (W)
5962-02548
Active
+ 20
160
80
+ 3.3
Single
AFL
Standard
66W - 120W
74
5962-96659
Active
+ 10
40
16
+ 8
Single
AFL
Standard
66W - 120W
82
5962-92351
Active
+/-0.4
40
16
+/-15
Dual
AHF
Standard
8W - 20W
78
Active
+ 4
400
160
+ 28
Single
AHP
Standard
66W - 120W
85
5962-92115
Active
+/-0.208
+ 2
40
16
+5, +/-12
+ 5
Triple
AHV
Standard
15W
76
5962-91575
Active
+/-0.5
40
17
+/-15
Dual
AHE
Standard
15W - 20W
82
Active
+/-0.625
40
17
+/-5
Dual
AHE
Standard
15W - 20W
82
5962-92111
Active
+/-0.5
40
16
+/-12
Dual
AHF
Standard
8W - 20W
77
Active
+ 10.67
160
80
+ 7.5
Single
AFL
Standard
66W - 120W
83
5962-94569
Active
+ 16
400
160
+ 5
Single
AFL
Standard
66W - 120W
82
Active
+ 13.5
400
160
+ 6
Single
AHP
Standard
66W - 120W
83
5962-02559
Active
+ 10
80
30
+ 9
Single
AFL
Standard
66W - 120W
83
Active
5.3
400
160
+/-15
Dual
AHP
Standard
66W - 120W
87
Active
+ 9
400
160
+ 12
Single
AHP
Standard
66W - 120W
85
5962-94568
Active
+ 1
40
16
+ 12
Single
AHF
Standard
8W - 20W
78
Active
+/-1.5
40
16
+/-5
Dual
AHV
Standard
15W
76
Active
+ 16
400
160
+ 5
Single
AHP
Standard
66W - 120W
82
5962-89683
Active
+ 3
40
17
+ 5
Single
AHE
Standard
15W - 20W
82
5962-05205
Active
+/-1.2
40
16
+/-5
Dual
AHF
Standard
8W - 20W
75
Active
+ 2.08
50
16
+ 12
Single
ATS
Standard
25W
75
5962-02560
Active
+ 9
80
30
+ 12
Single
AFL
Standard
66W - 120W
84
Active
48
38
+/-9.2
+ 3.4
Triple
HMA
50W
74
5962-91600
Active
+ 2.4
40
16
+ 5
Single
AHF
Standard
8W - 20W
76
Active
+ 16
40
16
+ 5
Single
AHP
Standard
66W - 120W
81
5962-99552
Active
+ 20
40
16
+ 3.3
Single
AFL
Standard
66W - 120W
74
5962-99553
Active
+ 20
400
160
+ 3.3
Single
AFL
Standard
66W - 120W
74
Active
12.8
40
16
+/-5
Dual
AHP
Standard
66W - 120W
81
5962-91774
Active
+/-0.5
40
16
+/-15
Dual
AHV
Standard
15W
76
Active
+ 10
400
160
+ 9
Single
AHP
Standard
66W - 120W
84
5962-92113
Active
+ 1
40
16
+ 15
Single
AHV
Standard
15W
76
5962-92040
Active
+/-0.625
40
17
+/-12
Dual
AHE
Standard
15W - 20W
82
5962-94623
Active
+/-0.1
+ 1
40
16
+/-15
+ 5
Triple
AHF
Standard
8W - 20W
75
5962-91625
Active
+ 1.333
40
17
+ 15
Single
AHE
Standard
15W - 20W
84
Active
5.3
40
16
+/-15
Dual
AHP
Standard
66W - 120W
85
5962-91580
Active
+ 1.667
40
17
+ 12
Single
AHE
Standard
15W - 20W
83
Active
+ 20
40
16
+ 3.3
Single
AHP
Standard
66W - 120W
72
5962-99609
Active
+/-4.5
160
80
+/-12
Dual
AFL
Standard
66W - 120W
85
5962-02557
Active
+ 16
80
30
+ 5
Single
AFL
Standard
66W - 120W
81
5962-92116
Active
+/-0.167
+ 2
40
16
+5, +/-12
+ 5
Triple
AHV
Standard
15W
76
5962-02558
Active
+ 10
80
30
+ 8
Single
AFL
Standard
66W - 120W
82
Active
+ 8
40
16
+ 15
Single
AHP
Standard
66W - 120W
85
Active
+ 3
40
16
+ 3.3
Single
AHF
Standard
8W - 20W
72
5962-94563
Active
+ 0.8
40
16
+ 15
Single
AHF
Standard
8W - 20W
80
Active
+ 8
400
160
+ 15
Single
AHP
Standard
66W - 120W
87
Active
+ 5
50
16
+ 5
Single
ATS
Standard
25W
75
Active
6.4
400
160
+/-12
Dual
AHP
Standard
66W - 120W
85
Active
12.8
400
160
+/-5
Dual
AHP
Standard
66W - 120W
82
Active
+ 9
40
16
+ 12
Single
AHP
Standard
66W - 120W
84
5962-92112
Active
+ 1.25
40
16
+ 12
Single
AHV
Standard
15W
76
5962-02552
Active
+ 8
160
80
+ 15
Single
AFL
Standard
66W - 120W
87
5962-02550
Active
+ 10
160
80
+ 9
Single
AFL
Standard
66W - 120W
84
5962-02555
Active
+/-3.3
160
80
+/-15
Dual
AFL
Standard
66W - 120W
87
Active
+ 20
400
160
+ 3.3
Single
AHP
Standard
66W - 120W
76
5962-95565
Active
+ 4
400
160
+ 28
Single
AFL
Standard
66W - 120W
85
5962-02564
Active
+/-4.5
80
30
+/-12
Dual
AFL
Standard
66W - 120W
84
5962-99608
Active
+ 16
160
80
+ 5
Single
AFL
Standard
66W - 120W
82
5962-94649
Active
+/-0.167
40
16
+/-15
Dual
ASA
Standard
5W
72
Pending
+ 0.75
50
15
+ 12
Single
ASAP
Standard
6W
71
Pending
+ 0.6
50
15
+ 5
Single
ASAP
Standard
6W
66
Pending
+/-0.6
50
15
+/-5
Dual
ASAP
Standard
6W
70
Pending
+/-0.6
50
15
+/-15
Dual
ASAP
Standard
6W
71
Pending
+/-0.6
50
15
+/-12
Dual
ASAP
Standard
6W
71
Obsolete
+ 0.75
50
15
+ 15
Single
ASAP
Standard
6W
71
Pending
+ 7.2
40
16
+ 11.1
Single
AFL
Standard
100W
84
Pending
+/-0.250
40
16
+/-10
Dual
ASA
Standard
5W
71
Pending
+ 0.1
40
18
+ 300
Single
ATW
Standard
30W
80
Pending
6.4
40
16
+/-12
Dual
AHP
Standard
66W - 120W
84
Pending
+ 4
40
16
+ 28
Single
AHP
Standard
66W - 120W
84
Pending
+ 10
40
16
+ 9
Single
AHP
Standard
66W - 120W
83
Pending
+ 10
40
16
+ 8
Single
AHP
Standard
66W - 120W
82
5962-94631
Active
+ 0.417
40
16
+ 12
Single
ASA
Standard
5W
74
5962-94625
Active
+ 2.5
40
16
+ 12
Single
ATR
Standard
30W
80
5962-02565
Active
+/-3.3
80
30
+/-15
Dual
AFL
Standard
66W - 120W
85
5962-02553
Active
+ 4
160
80
+ 28
Single
AFL
Standard
66W - 120W
85
5962-91579
Active
+ 6
40
19
+ 5
Single
ATW
Standard
30W
81
5962-02561
Active
+ 8
80
30
+ 15
Single
AFL
Standard
66W - 120W
85
5962-94721
Active
+ 16
40
16
+ 5
Single
AFL
Standard
66W - 120W
81
5962-02563
Active
+/-8
80
30
+/-5
Dual
AFL
Standard
66W - 120W
81
5962-94624
Active
+ 6
40
16
+ 5
Single
ATR
Standard
30W
78
5962-95501
Active
+/-8
400
160
+/-5
Dual
AFL
Standard
66W - 120W
82
5962-92110
Active
+ 2.5
40
18
+ 12
Single
ATW
Standard
30W
82
5962-93158
Active
+/-0.625
+ 3
40
16
+5, +/-12
+ 5
Triple
ATR
Standard
30W
76
5962-02549
Active
+ 10
160
80
+ 8
Single
AFL
Standard
66W - 120W
83
5962-95648
Active
+/-0.208
40
16
+/-12
Dual
ASA
Standard
5W
72
5962-91602
Active
+/-0.208
+ 2
40
16
+5, +/-12
+ 5
Triple
ATO
Standard
15W
78
5962-90954
Active
+/-0.167
+ 2
40
16
+5, +/-12
+ 5
Triple
ATO
Standard
15W
78
5962-94722
Active
+ 9
40
16
+ 12
Single
AFL
Standard
66W - 120W
83
5962-94570
Active
+ 8
400
160
+ 15
Single
AFL
Standard
66W - 120W
87
5962-92109
Active
+/-1.25
40
18
+/-12
Dual
ATW
Standard
30W
83
5962-95796
Active
+/-4.5
40
16
+/-12
Dual
AFL
Standard
66W - 120W
84
5962-95532
Active
+/-3.3
400
160
+/-15
Dual
AFL
Standard
66W - 120W
87
5962-94627
Active
+/-1.25
40
16
+/-12
Dual
ATR
Standard
30W
80
5962-94629
Active
+ 1
40
16
+ 5
Single
ASA
Standard
5W
70
5962-99518
Active
+/-4.5
400
160
+/-12
Dual
AFL
Standard
66W - 120W
85
5962-95795
Active
+/-8
40
16
+/-5
Dual
AFL
Standard
66W - 120W
81
5962-91613
Active
+/-1
40
18
+/-15
Dual
ATW
Standard
30W
83
5962-02556
Pending
+ 20
80
30
+ 3.3
Single
AFL
Standard
66W - 120W
74
5962-94626
Active
+ 2
40
16
+ 15
Single
ATR
Standard
30W
80
5962-91773
Pending
+ 3
40
16
+ 5
Single
AHV
Standard
15W
76
5962-91599
Active
+ 2
40
17
+ 15
Single
ATW
Standard
30W
83
5962-02562
Active
+ 4
80
30
+ 28
Single
AFL
Standard
66W - 120W
84
5962-02551
Active
+ 9
160
80
+ 12
Single
AFL
Standard
66W - 120W
85
5962-94753
Active
+ 9
400
160
+ 12
Single
AFL
Standard
66W - 120W
85
5962-94630
Active
+ 0.333
40
16
+ 15
Single
ASA
Standard
5W
74
5962-94628
Active
+/-1
40
16
+/-15
Dual
ATR
Standard
30W
80
5962-95534
Active
+ 13.5
400
160
+ 6
Single
AFL
Standard
66W - 120W
83
5962-92159
Active
+/-0.5
+ 3
40
16
+/-15
+ 5
Triple
ATR
Standard
30W
76
5962-94723
Active
+ 8
40
16
+ 15
Single
AFL
Standard
66W - 120W
85
5962-92114
Pending
+/-0.625
40
16
+/-12
Dual
AHV
Standard
15W
76
5962-95535
Active
+ 10
400
160
+ 9
Single
AFL
Standard
66W - 120W
84
5962-94724
Active
+/-3.3
40
16
+/-15
Dual
AFL
Standard
66W - 120W
85
5962-96899
Active
+ 4
40
16
+ 28
Single
AFL
Standard
66W - 120W
84
5962-02554
Active
+/-8
160
80
+/-5
Dual
AFL
Standard
66W - 120W
82
Pending
+ 6.06
50
16
+ 3.3
Single
ATS
Standard
25W
68
Pending
+/-4
50
16
+/-5
Dual
ATS
Standard
25W
75
Pending
+/-1.67
50
16
+/-12
Dual
ATS
Standard
25W
75
Pending
+/-1.33
50
16
+/-15
Dual
ATS
Standard
25W
75
Pending
+ 1.333
50
16
+ 15
Single
ATS
Standard
25W
75
Active
+/-0.6
40
16
+/-5
Dual
ASA
Standard
5W
70
Pending
+ 7.5
40
16
+ 3.3
Single
ATR
30W
74
Pending
Pending
400
160
+ 8
Single
AFL
Standard
66W - 120W

Products you can count on in the toughest environments

High reliability power management products

Press Releases

IR HiRel DC-DC Converter Family Increases Robustness with Added Input Protection and Reduced Internal Component Count for Military and Aerospace Applications

Read More

International Rectifier Introduces Standard Microcircuit Drawing-Certified DC-DC Converters with Up to 80% Efficiency at 25°C

Read More

International Rectifier Introduces Two 120V Input, Hermetically-Sealed, DC-DC Converters that Handle 25% More Power

Read More

Quality Conformance Testing

Unlike standard commercial products, HiRel products must be submitted to various levels of quality conformance testing to ensure that the products are capable of performing to specifications in the often harsh environments of military and space applications. Both the United States and European community have each developed specifications that detail the sequence of quality conformance testing.

In the United States, the Defense Logistics Agency (DLA) is the controlling agency and has issued specifications that govern the quality conformance testing sequence performed on semiconductor devices and hybrid modules, namely MIL-PRF-19500/MIL-STD-750, MIL-PRF-38534/MIL-STD-883 and MIL-PRF-38535/MIL-STD-883.

MIL-PRF-38534/MIL-STD-883 are the controlling specifications for power hybrids. MIL-STD-883 directs hybrids te be manufactured to class H or class K.

International Rectifier HiRel Products Group manufactures and tests hermetic products to one of three distinct quality conformance levels: (1) commercial hermetic, (2) source control drawing (SCD), or (3) MIL-PRF-38534, MIL-PRF-38535 qualified. The HiRel Products Group also provides screened plastic encapsulated devices.

  
 

Screening and Quality Conformance Inspection Requirements

QPL Listing - DC-DC

 


Glossary

Class H: Class H is the standard military quality level provided in MIL-PRF-38534, General Specification for Hybrid Microcircuits. It is intended for space applications.

Level B: Class level B defines the screening requirements for high reliability military applications as specified in MIL-STD-883 and is intended for use in class H products.

Level S: Class level S defines the screening requirements for high reliability space applications as specified in MIL-STD-883 and is intended for use in class K products.

JAN: JAN (Joint Army Navy) is the prefix assigned by the DSCC to designate devices on the DSCC qualified parts list.

JANTX: Military screening level as specified in MIL-PRF-19500 for a DSCC qualified device.

JANTXV: Military with visual inspection screening level as specified in MIL-PRF-19500 for a DSCC qualified device.

JANS: Space level screening as specified in MIL-PRF-19500 for a DSCC qualified device.

 

Screening and Quality Conformance Inspection Requirements

For further parametric data and packaging information, activate the Single, Dual, or Triple links below in the table heading.
 
Output Power HiRel Hermetic Rad-Tolerant
TID: 25-30Krads
SEE: 37-60MeV
Rad-Hard
TID: 100K-1Mrads
SEE: 37-83MeV
Single Dual Triple Single Dual Triple Single Dual Triple Quad (4)
5W ASA ASA - AMA AMA - - MA,
ML
MA -
6W ASAP(4) ASAP(4) - - - - - - - -
10W - - - - - - S S - -
- - - - - - - MAH MAH MAH
12W AHF AHF - AMF AMF - - - - -
15W AHV AHV AHV, ATO - - - - MB MB -
15W AHE AHE AHFP(4) - - - - - -
20W HTA(1) HTA(1) - - - - - MBH(4) MBH(4) -
AHFP(4), AHE AHFP(4), AHE - - - - - - - -
25W ATS ATS - M3L M3L - - - - -
30W ATR ATR ATR AMR AMR - ARH - ARM -
ATW ATW ATRP(4) - - - LS LS ART ART(4)
- - - - - - LSO(3) LSO(3) - -
- - - - - - SBB - - -
40W ATRP(4) ATRP(4) HM(4) M3H M3H M3H M3G M3G M3G -
50W - - - - - - GH - - -
55W HTH(2) - - - - - - - - -
60W - - - - - - ZA(4) - EA(4) -
66W AFL, AHP - - - - - - - - -
80W AFL, AHP AFL, AHP - - - - ZA(4) - - -
90W AFL, AHP - - - - - - - - -
92W HTM(2) - - - - - - - - -
96W - AFL, AHP - - - - - - - -
100W - AFL, AHP - - - - ZA(4) - - -
108W AFL, AHP - - - - - - - - -
112W AFL, AHP - - - - - - - - -
120W AFL, AHP - - - - - - - - -
160W - - - - - - - - EB(4) -
250W - - - - - - ZB(4) - - -
350W - - - - - - - - EC(4) -
 

(1)  +185oC rated temperature
(2)  +165oC rated temperature
(3)  Includes output overvoltage protection and input current telemetry
(4)  Contact Sales and Distribution

 

Military DC-DC Converters

 

Complete HiRel Product Nomenclature

Collateral

AN-1067
High Reliability DC-DC Selection Guide

Download