template irg8p50n120kd-epbf a g k # Saber Model with Thermal RC Network #************************************* # Model Generated by MODPEX * #Copyright(c) Symmetry Design Systems* # All Rights Reserved * # UNPUBLISHED LICENSED SOFTWARE * # Contains Proprietary Information * # Which is The Property of * # SYMMETRY OR ITS LICENSORS * #Commercial Use or Resale Restricted * # by Symmetry License Agreement * #************************************* # Model generated on Jun 5, 15 # MODEL FORMAT: Saber # Symmetry IGBT Model (Version 1.0) electrical a,g,k { template irg8p50n120kd-epbf_d p n electrical p,n { # BODY_BEGIN spd..model ddirg8p50n120kd-epbf_d=( is=1.23802e-09,rs=0.0271963,n=2,eg=1.3, xti=0.902158,bv=1200,ibv=0.00025,cjo=2.33782e-09, vj=0.4,m=0.547985,fc=0.5,tt=1e-07, kf=0,af=1) spd.d p n =model=ddirg8p50n120kd-epbf_d } template irg8p50n120kd-epbf_i a g k electrical a,g,k { # BODY_BEGIN spm..model ms=(type=_n,level=1, vto=5.96733,kp=1.76924,lambda=0,rs=1.17126e-06, rd=1.16479e-06,cgso=3.0371e-05) spq..model qsub=(type=_p, is=2.83093e-15,bf=311.597,nf=0.85,vaf=3693.06, ikf=588.486,ise=1.72344e-09,ne=1.35953,br=0.1, nr=1.5,var=1150.38,ikr=999.776,isc=1e-17, nc=1,rb=0.00176238,irb=2714.73,rbm=8.55217e-05, re=1e-08,rc=1e-08,xtb=0,xti=0, eg=0.5,cjc=7.92393e-10,vjc=0.4,mjc=0.470505, cje=1.58479e-08,vje=0.4,mje=0.9,tf=1.46752e-07) # Default values used in DCAP: # RS=0 EG=1.11 XTI=3.0 TT=0 # BV=infinite IBV=1mA spd..model dcap=(is=1e-32,n=50, cjo=1.60914e-09,vj=0.4,m=0.60776,fc=0.5) # Default values used in DL: # EG=1.11 XTI=3.0 TT=0 CJO=0 # RS=0 BV=infinite IBV=1mA spd..model dl=(is=1e-10,n=0.4) spm.m1 n7 n6 n4 n4 =model=ms,l=100u,w=100u spq.q1 n4 n7 a a=model=qsub,off=1 spr.rds n7 n4 =1e8 spr.rer n4 k =0.00830424 spr.rg n6 g =8.41009 spr.rl n10 n11 =1 spd.d2 n12 n11 =model=dcap spd.d3 0 n11 =model=dl spv.vfi2 n12 0 =0 spf.fi2 n6 n7 i(spv.vfi2) =-1 spe.ev n10 0 n7 n6 =1 spc.cap n10 n13 =1.10685e-08 spr.rcap n10 n14 =1 spd.d4 0 n14 =model=dl spv.vfi1 n13 n14 =0 spf.fi1 n6 n7 i(spv.vfi1) =-1 } # Saber Thermal Model # The customer will have to have the Optional Template Library License # to run this part of the library template irg8p50n120kd-epbf_it tj tc { rtherm.r1 tj n2 = 0.1142 rtherm.r2 n2 n1 = 0.1553 rtherm.r3 n1 tc = 0.0914 ctherm.c1 tj n2 = 0.00416 ctherm.c2 n2 n1 = 0.02508 ctherm.c3 n1 tc = 0.20523 } irg8p50n120kd-epbf_i.igbt a g k irg8p50n120kd-epbf_d.diode p n