template irg4pc40u c g e #************************************* # Model Generated by MODPEX * #Copyright(c) Symmetry Design Systems* # All Rights Reserved * # UNPUBLISHED LICENSED SOFTWARE * # Contains Proprietary Information * # Which is The Property of * # SYMMETRY OR ITS LICENSORS * #Commercial Use or Resale Restricted * # by Symmetry License Agreement * #************************************* # Model generated on Mar 3, 97 # MODEL FORMAT: Saber # Symmetry IGBT Model (Version 1.0) electrical c,g,e { # BODY_BEGIN # Default values used in MS: # The voltage-dependent capacitances are # not included. Other default values are: # LD=0 CBD=0 CBS=0 CGBO=0 spm..model ms=(type=_n,level=1, vto=5.94387,kp=0.214059,lambda=1.66093,rs=1e-06, rd=1e-06,cgso=2.00187e-05) spq..model qsub=(type=_p, is=1e-17,bf=4.47778,nf=0.85,vaf=88.0979, ikf=493.458,ise=3.54824e-11,ne=1.47478,br=10.1202, nr=0.75,var=142.787,ikr=1134.64,isc=9.98961e-12, nc=1.98439,rb=0.0001,irb=1073.98,rbm=0.0001, re=1e-08,rc=0.000222891,xtb=0,xti=3.54269, eg=1.2,cjc=1.45053e-09,vjc=1.82764,mjc=0.9, cje=2.90106e-08,vje=0.4,mje=0.9,tf=2.99912e-09) # Default values used in DCAP: # RS=0 EG=1.11 XTI=3.0 TT=0 # BV=infinite IBV=1mA spd..model dcap=(is=1e-32,n=50, cjo=4.12619e-09,vj=0.4,m=0.9,fc=0.5) # Default values used in DL: # EG=1.11 XTI=3.0 TT=0 CJO=0 # RS=0 BV=infinite IBV=1mA spd..model dl=(is=1e-10,n=0.4) spm.m1 n7 n6 n4 n4 =model=ms,l=100u,w=100u spq.q1 n4 n7 c c=model=qsub,off=1 spr.rds n7 n4 =1e8 spr.rer n4 e =0.0005 spr.rg n6 g =13.9403 spr.rl n10 n11 =1 spd.d2 n12 n11 =model=dcap spd.d3 0 n11 =model=dl spv.vfi2 n12 0 =0 spf.fi2 n6 n7 i(spv.vfi2) =-1 spe.ev n10 0 n7 n6 =1 spc.cap n10 n13 =1.09768e-09 spr.rcap n10 n14 =1 spd.d4 0 n14 =model=dl spv.vfi1 n13 n14 =0 spf.fi1 n6 n7 i(spv.vfi1) =-1 }