ORing and DPA Architecture
(Server/Telecom)
|
|
The Active ORing combines two or more power sources to create a redundant power source, preserving
the input power supply in case one of the input sources fails. In the event of an input power failure,
the active ORing circuit disconnects the non-functioning power source as quickly as possible to prevent
the system bus voltage from falling, and prevents large peak reverse currents.
|

Active ORing
|
The Active Solution

|
- VIN-OUT drop : 85mV (85% reduction in power losses vs. diode)
- Size: 50% smaller than the traditional solution with diodes
- Protection Features: Diagnostic Capability and Increased System Up-Time
|
AC-DC Active ORing Switches
|
DC-DC Active ORing Switches
Recommended Power Level for -48V System |
FET Voltage |
RDS(on) max. @ 10VGS |
Part Number |
Package |
| 180W to 370W |
100V |
13 milliOhms |
IRF6644 |
M-Can DirectFET |
| 100W to 200W |
22 milliOhms |
IRF6662 |
M-Can DirectFET |
| 70W to 140W |
35 milliOhms |
IRF6645 |
S-Can DirectFET |
| 40W to 80W |
62 milliOhms |
IRF6655 |
S-Can DirectFET |
|
|
|